142A171-4

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

142A171-4

5915-01-352-9878

5915 - Filters and Networks

Lockheed Martin Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    2.088 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.120 inches nominal

  • Operating Temp Range

    -40.0/+125.0 deg celsius

  • End Item Identification

    5895012993419

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference .

  • Load Impedance Per Function

    50.0 ohms 1st radio interference .

  • Load Impedance Per Function

    50.0 ohms 4th radio interference .

  • Load Impedance Per Function

    50.0 ohms 5th radio interference .

  • Load Impedance Per Function

    50.0 ohms 6th radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 5th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Inclosure Type

    encased

  • Features Provided

    fungus resistant and shock resistant

  • Functional Terminal Type And Quantity

    25 friction w/grounding strap and pin input-output

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 1st radio interference .

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 2nd radio interference .

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 4th radio interference .

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 5th radio interference .

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 6th radio interference .

  • Body Material

    metal

  • Maximum Dielectric Withstanding Dc Voltage

    150.0 volts at sea level

  • Special Features

    25 filtered contacts

  • Overall Height

    0.876 inches nominal

  • Overall Width

    0.494 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.852 inches nominal

  • Vibration Resistance Range In Hertz

    10.0/ 55.0

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference .

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference .

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 1st radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 2nd radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 3rd radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 4th radio interference .

  • Maximum Voltage Drop Per Function

    0.5 volts dc 6th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Operating Voltage Rating And Type Per Function

    50.0 volts dc 3rd radio interference .

  • Style Designator

    45 filter connector

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.