90C01-6673

Switches

SWITCH,PRESSURE-THERMOSTATIC

90C01-6673

5930-01-355-7100

5930 - Switches

Carrier Corporation

SWITCH,PRESSURE-THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    4.0 amperes inductive load third voltage

  • Temp Sensing Element Type

    capillary tube-bulb

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, one position momentary

  • Contact Load Current Rating

    2.5 amperes inductive load seventh voltage

  • Contact Voltage Rating In Volts

    230.0 dc at sea level sixth voltage

  • Contact Load Current Rating

    2.0 amperes inductive load eighth voltage

  • Pressure Switch Type

    differential

  • Bulb Diameter

    3.000 inches nominal

  • Body Height

    2.750 inches nominal

  • Longest Vertical Distance Between Mounting Centers

    3.281 inches nominal

  • Overall Height

    5.689 inches nominal

  • Contact Load Current Rating

    8.0 amperes inductive load second voltage

  • Overall Length

    5.188 inches nominal

  • Capillary Tube Length

    120.0 inches nominal

  • Contact Load Current Rating

    16.0 amperes inductive load first voltage

  • Contact Action Stimulus

    increase

  • Mounting Method

    bracket and unthreaded hole

  • Contact Voltage Rating In Volts

    115.0 dc at sea level fifth voltage

  • Precious Material And Location

    contacts silver

  • Precious Material

    silver

  • Contact Voltage Rating In Volts

    230.0 ac at sea level second voltage

  • Overall Width

    2.812 inches nominal

  • Mounting Facility Pattern

    isosceles triangle

  • Contact Stimulus Rating

    43.25 actuation point minimum degrees fahrenheit and 38.25 deactuation point minimum degrees fahrenheit and 44.75 actuation point maximum degrees fahrenheit and 39.75 deactuation point maximum degrees fahrenheit

  • Unthreaded Mounting Hole Diameter

    0.282 inches nominal

  • Bulb Length

    0.375 inches nominal

  • Contact Load Current Rating

    4.8 amperes inductive load sixth voltage

  • Contact Voltage Rating In Volts

    550.0 ac at sea level fourth voltage

  • Media For Which Designed

    gas

  • Contact Adjustment Type

    external actuation point screw and external deactuation point screw

  • Contact Voltage Rating In Volts

    440.0 ac at sea level third voltage

  • Shortest Horizontal Distance Between Mounting Centers

    0.656 inches nominal

  • Longest Horizontal Distance Between Mounting Centers

    2.406 inches nominal

  • Contact Voltage Rating In Volts

    550.0 dc at sea level eighth voltage

  • Contact Load Current Rating

    3.2 amperes inductive load fourth voltage

  • Terminal Type

    screw

  • Style Designator

    rectangular

  • Contact Voltage Rating In Volts

    440.0 dc at sea level seventh voltage

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Contact Adjustability

    actuation point adjustable, preset and deactuation point adjustable, preset

  • Contact Load Current Rating

    9.6 amperes inductive load fifth voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...