203-222-1-41F-103-4-1-1

Circuit Breakers

CIRCUIT BREAKER

203-222-1-41F-103-4-1-1

5925-01-356-8076

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.000 inches nominal

  • Body Height

    1.770 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.250 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 clip

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    2.600 ounces

  • Body Style

    11b multipole-single actuator type

  • Body Width

    2.170 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.250 inches minimum and 1.260 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.625 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches nominal

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.050 minimum at 200 pct and 0.950 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant and vibration resistant

  • Special Features

    rocker handle neon illuminated

  • Terminal Type And Quantity

    6 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...