MIL-T-27/357
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
MIL-T-27/357
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performance r
-
Test Data Document
81349-mil-t-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Winding Tap Location (Non-Core)
center tap single component single secondary
-
Overall Diameter
0.490 inches minimum and 0.510 inches maximum
-
Specification/Standard Data
81349-mil-t-27/357 government specification
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Frequency Rating
300.0 hertz minimum single component and 75.0 kilohertz maximum single component
-
Maximum Operating Temp
130.0 deg celsius
-
Mounting Method
terminal single group
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
-
Reliability Indicator
not established
-
Frequency Response Tolerance In Decibels (Non-Core)
-3.0/+3.0 single component
-
Impedance Rating In Ohms
600.0 nominal single component single primary
-
Maximum Transformer Power Rating
0.6 watts single component
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Current
5.5 milliamperes maximum of standard range b single component single secondary
-
Overall Length
0.350 inches maximum
-
Features Provided
tinned wire leads
-
Unpackaged Unit Weight (Non-Core)
5.0 grams
-
Primary To Secondary Turn Ratio
1 to 1 single component
-
Impedance Rating In Ohms
600.0 nominal single component single secondary
-
Terminal Type And Quantity
7 wire lead