34064310-001
Coils and Transformers
TRANSFORMER,POWER
34064310-001
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.050 inches nominal single mounting facility single center group
-
Overall Length
3.730 inches minimum and 3.750 inches maximum
-
Winding Operating Voltage
200.00 ac volts nominal single component single primary
-
Overall Height
1.600 inches maximum
-
Body Width
2.880 inches minimum and 2.900 inches maximum
-
Transformer Winding Connection Type
wye-delta
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Special Features
secondary windings 1,2,and 3,have common center taps connected to a single terminal; also this item is shock resistant.
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Maximum Operating Temp
125.0 deg celsius
-
Terminal Type And Quantity
17 pin
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Thread Series Designator
unc single group
-
Nominal Thread Size
0.138 inches single group
-
Thread Direction (Non-Core)
err-070
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
three phase to three phase single component and three phase to single phase single component