AP117-26010-1

Circuit Breakers

CIRCUIT BREAKER

AP117-26010-1

5925-01-360-8127

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac second location

  • Body Width

    1.937 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Terminal Type And Quantity

    6 screw

  • Frequency In Hertz

    50.0 first location or 50.0 second location or 60.0 second location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac second location

  • Thread Series Designator

    unef

  • Unpackaged Unit Weight

    5.400 ounces

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Features Provided

    high inrush protection

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 maximum at 200 pct third location

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes dc third location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.950 maximum at 200 pct second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Frequency In Hertz

    60.0 first location

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac first location

  • Actuator Position Designation

    at pole two

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac first location

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct first location and 0.055 minimum at 200 pct second location and 0.060 minimum at 200 pct third location and 0.950 maximum at 200 pct first location

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...