APL-3REC4-24676-1
Circuit Breakers
CIRCUIT BREAKER
APL-3REC4-24676-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct all locations and 7.000 maximum at 200 pct all locations
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Switch Location And Position Designation
internal at pole two and internal at pole five
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Unpackaged Unit Weight
33.600 ounces
-
Terminal Type And Quantity
18 threaded stud
-
External Actuator Linkage Arrangement
one, two, and three linked and four, five, and six linked
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Facility Type And Quantity
18 threaded hole
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
-
Body Width
6.765 inches maximum
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Special Features
poles seven,eight and nine have external actuator arrangement linkage. pole eight also has an auxiliary switch
-
Switch Terminal Type
pin
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Mounting Surface To Terminal End Distance
2.625 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Pole Quantity
9
-
Case Material
plastic
-
Manual Actuator Type And Quantity
9 toggle