03930677-006
Circuit Breakers
CIRCUIT BREAKER
03930677-006
Getronics Government Solutions Llc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 toggle
-
Bushing Length
0.458 inches minimum and 0.478 inches maximum
-
Unpackaged Unit Weight
2.400 ounces
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
1.204 inches minimum and 1.314 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.050 inches minimum and 1.155 inches maximum
-
Body Length
1.365 inches minimum and 1.385 inches maximum
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Terminal Type And Quantity
4 tab, solder lug
-
Center To Center Distance Between Terminals Parallel To Width
0.615 inches minimum and 0.635 inches maximum
-
Thread Series Designator
un
-
Body Height
1.685 inches minimum and 1.745 inches maximum
-
Case Material
plastic
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct all locations and 2.000 maximum at 200 pct all locations
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.329 inches minimum and 1.339 inches maximum
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Pole Quantity
2
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.615 inches minimum and 0.635 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Special Features
white paddle handle