12562026-2

Circuit Breakers

CIRCUIT BREAKER

12562026-2

5925-01-361-6928

5925 - Circuit Breakers

U S Army Armament Research &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent single location

  • Actuator Position Designation

    at pole two

  • Pole Quantity

    1

  • Nominal Thread Size

    0.138 inches and 0.500 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 threaded bushing w/panel seal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof and corrosion resistant and moisture resistant and fungus resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.651 inches minimum and 0.661 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Unpackaged Unit Weight

    3.000 ounces

  • Thread Series Designator

    unc and un

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Reset Method

    manual

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 1.200 maximum at 200 pct single location

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...