Technical Characteristics
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
3.5 amperes ac single location
-
Bushing Length
0.380 inches maximum
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Body Width
0.625 inches maximum
-
Body Style
single pole type
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Length
1.562 inches maximum
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Nominal Thread Size
0.375 inches
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reset Method
manual
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.500 minimum at 200 pct single location and 30.000 maximum at 200 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Trip Release Method
magnetic single location