Technical Characteristics
-
Internal Trip Release Configuration
relay trip fourth location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Frequency In Hertz
400.0 first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct first location
-
Circuit Protection Type
overcurrent first location
-
Actuator Function
trip-reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct third location and 2.000 minimum at 200 pct first location and 2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location
-
Circuit Protection Type
overcurrent second location
-
Mounting Facility Type And Quantity
8 threaded hole
-
Circuit Protection Type
undervoltage fourth location
-
Mounting Surface To Terminal End Distance
2.611 inches nominal
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Circuit Protection Type
overcurrent third location
-
Trip Release Characteristic
instantaneous fourth location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct third location
-
Frequency In Hertz
60.0 fourth location
-
Frequency In Hertz
400.0 third location
-
Manual Actuator Type And Quantity
4 toggle
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Pole Quantity
4
-
Boss Height
0.140 inches nominal
-
Body Length
2.500 inches nominal
-
Trip Release Characteristic
time delay third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 second location
-
Internal Trip Release Configuration
series trip third location
-
Trip Release Characteristic
time delay second location
-
Nominal Thread Size
0.138 inches
-
Body Width
3.000 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Internal Trip Release Configuration
series trip second location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Trip Release Characteristic
time delay first location
-
Internal Trip Release Configuration
series trip first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations