9124-10309
Relays and Solenoids
RELAY,ELECTROMAGNETIC
9124-10309
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
-
Time Delay
0.01 seconds maximum fixed release time
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac inductive load and 50.0 amperes dc inductive load
-
Terminal Type And Quantity
12 threaded stud all functions
-
Overall Height
2.438 inches nominal
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac motor load and 50.0 amperes dc motor load
-
Winding Dc Resistance Rating
50.0 ohms nominal single winding
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal single mounting facility
-
Time Delay
0.002 seconds maximum fixed operate time
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, double make, momentary action
-
Overall Length
3.730 inches maximum
-
Fragility Factor
moderately rugged
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.687 inches nominal single mounting facility
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Test Data Document
53711-5946431 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Environmental Protection
hermetic
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Overall Width
3.305 inches maximum
-
Winding Quantity
1
-
Nonpile-Up Auxiliary Contact Arrangement
1 two circuit, double break/double make, one position momentary
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac resistive load and 50.0 amperes dc resistive load