3000701
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
3000701
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.000 inches nominal
-
Operating Current Rating Per Function In Amps
12.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Inclosure Type
encased
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 1st radio interference 1st function and 250.0 volts dc 1st radio interference 1st function
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
2 tab w/screw input 1st function
-
Overall Height
2.000 inches nominal
-
Functional Terminal Type And Quantity
1 tab w/screw ground 3rd function
-
Functional Terminal Type And Quantity
2 tab w/screw output 2nd function
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Operating Voltage Rating And Type Per Function
250.0 volts dc 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.375 inches nominal
-
Operating Current Rating Per Function In Amps
12.0 1st radio interference