6644288
Filters and Networks
FILTER,BAND PASS
6644288
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
50.0 ohms 4th band pass
-
Inclosure Type
encased
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Load Impedance Per Function
50.0 ohms 3rd band pass
-
Features Provided
shock resistant and active and fungus resistant and moisture resistant and gaussian response and salt water resistant
-
Operating Temp Range
+0.0/+70.0 deg celsius
-
Body Material
metal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
-
Functional Terminal Type And Quantity
4 pin input 1st function
-
Reference Frequency Per Function
62.5 hercules no.5599.1 pulses per second
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Load Impedance Per Function
50.0 ohms 4th band pass
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Frequency Band Width Per Function
62.86 megahertz 4th band pass
-
Voltage Standing Wave Ratio Per Function
1.7 1st band pass
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Reference Frequency Per Function
61.88 hercules no.5599.1 two phase to two phase
-
Voltage Standing Wave Ratio Per Function
1.7 2nd band pass
-
Unthreaded Mounting Hole Diameter
0.140 inches nominal
-
Overall Height
0.900 inches maximum
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Frequency Band Width Per Function
65.04 megahertz 1st band pass
-
Voltage Standing Wave Ratio Per Function
1.7 3rd band pass
-
Voltage Standing Wave Ratio Per Function
1.7 4th band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.367 inches minimum and 3.383 inches maximum
-
Body Width
1.870 inches nominal
-
Frequency Band Width Per Function
63.78 megahertz 2nd band pass
-
Body Length
3.940 inches minimum and 3.960 inches maximum
-
Reference Frequency Per Function
60.94 hercules no.5599.1 two phase to three phase
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Source Impedance Rating Per Function
50.0 ohms 3rd band pass
-
Frequency Band Width Per Function
57.14 megahertz 4th band pass and 59.97 megahertz 1st band pass and 59.97 megahertz 2nd band pass and 59.98 megahertz 3rd band pass and 61.89 megahertz 3rd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.150 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Reference Frequency Per Function
60.0 hercules no.5599.1 hertz