Technical Characteristics
-
Special Features
pressure switch must close within2 seconds maximum upon rapid pressure decay. hermetic seal capable of meeting 1 x 10-7 scc/sec maximum helium leakrate at 1000 psig port pressure.......minimum service life of 10,000 cycles.normal operating range 0-2600
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum
-
Nonpile-Up Contact Arrangement
2 pole, double throw, one position momentary
-
Terminal Type
connector, receptacle
-
Contact Load Current Rating
175.0 milliamperes inductive load single voltage
-
Mounting Method
flange
-
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Contact Stimulus Rating
400.00 actuation point nominal pounds per square inch and 225.00 deactuation point nominal pounds per square inch
-
Overall Height
2.350 inches nominal
-
Proof Pressure
3150.00 pounds per square inch
-
Overall Width
1.250 inches nominal
-
Media For Which Designed
gas or liquid
-
Style Designator
cylindrical w/flange
-
Overall Length
1.250 inches nominal
-
Body Height
2.350 inches nominal
-
Pressure Switch Type
gage
-
Contact Action Stimulus
increase
-
~1
psig