4MC10-200/5-P/P

Filters and Networks

FILTER,BAND PASS

4MC10-200/5-P/P

5915-01-376-1992

5915 - Filters and Networks

K&L Microwave Inc.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 4th band pass

  • Average Power Rating Per Function

    2.0 watts 2nd band pass

  • Reference Frequency Per Function

    200.0 hercules no.5599.1 two phase to three phase

  • Inclosure Type

    encased

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Reference Frequency Per Function

    200.0 hercules no.5599.1 two phase to two phase

  • Frequency Band Width Per Function

    202.50 megahertz 2nd band pass

  • Body Length

    2.250 inches nominal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Average Power Rating Per Function

    2.0 watts 3rd band pass

  • Frequency Band Width Per Function

    202.50 megahertz 3rd band pass

  • Frequency Band Width Per Function

    202.50 megahertz 4th band pass

  • Body Height

    0.690 inches nominal

  • Voltage Standing Wave Ratio Per Function

    1.5 1st band pass

  • Source Impedance Rating Per Function

    50.0 ohms 1st band pass

  • Load Impedance Per Function

    50.0 ohms 3rd band pass

  • End Item Identification

    5895-01-201-8638 synthesizer,electrical frequency

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Overall Height

    1.030 inches nominal

  • Body Material

    metal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Voltage Standing Wave Ratio Per Function

    1.5 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Voltage Standing Wave Ratio Per Function

    1.5 3rd band pass

  • Load Impedance Per Function

    50.0 ohms 4th band pass

  • Average Power Rating Per Function

    2.055 watts 4th band pass

  • Vibration Resistance Range In Hertz

    +5.0/+1000.0

  • Source Impedance Rating Per Function

    50.0 ohms 2nd band pass

  • Voltage Standing Wave Ratio Per Function

    1.5 4th band pass

  • Mounting Facility Screw Thread Series Designator

    unc

  • Frequency Band Width Per Function

    197.50 megahertz 3rd band pass and 197.50 megahertz 4th band pass and 197.50 megahertz 1st band pass and 197.50 megahertz 2nd band pass and 202.50 megahertz 2nd band pass

  • Load Impedance Per Function

    50.0 ohms 1st band pass

  • Operating Temp Range

    -20.0/+85.0 deg celsius

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Functional Terminal Type And Quantity

    1 pin output 2nd function

  • Source Impedance Rating Per Function

    50.0 ohms 3rd band pass

  • Nominal Thread Size

    0.086 inches

  • Reference Frequency Per Function

    200.0 hercules no.5599.1 hertz

  • Average Power Rating Per Function

    2.0 watts 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Reference Frequency Per Function

    200.0 hercules no.5599.1 pulses per second

  • Load Impedance Per Function

    50.0 ohms 2nd band pass

  • Body Width

    0.380 inches nominal

  • Features Provided

    chebyschev response and shock resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...