IT3007-2A
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
IT3007-2A
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Voltage Drop Per Function
1.1 volts ac 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
17.280 inches nominal
-
Body Height
5.750 inches nominal
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Operating Current Rating Per Function In Amps
60.0 2nd radio interference
-
Maximum Voltage Drop Per Function
1.1 volts ac 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Body Material
metal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
40.0 and 50.0 and 20.0 and 60.0 and 60.0 and 60.0
-
Overall Length
31.186 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
0.5 and 0.15 and 100.0 and 0.1 and 1.0 and 1000.0
-
Body Length
28.000 inches nominal
-
Functional Terminal Type And Quantity
2 tab, solder lug input 1st function
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
60.0 1st radio interference
-
Body Width
16.000 inches nominal
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Unpackaged Unit Weight
15.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
14.000 inches nominal
-
Functional Terminal Type And Quantity
2 tab, solder lug output 2nd function
-
Maximum Dielectric Withstanding Dc Voltage
2200.0 volts at sea level
-
Features Provided
heat resistant and shock resistant and moisture resistant
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Mounting Facility Type And Quantity
26 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Unthreaded Mounting Hole Diameter
0.219 inches nominal