Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.650 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference and 60.0 volts dc 2nd radio interference .
-
Nominal Thread Size
0.086 inches
-
Body Material
metal
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at altitude
-
Overall Length
2.840 inches nominal
-
Overall Height
1.130 inches nominal
-
Overall Width
1.200 inches nominal
-
Operating Temp Range
-55.0/+110.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference .
-
Load Impedance Per Function
50.0 ohms 1st radio interference .
-
Operating Current Rating Per Function In Amps
2.0 1st radio interference .
-
Inclosure Type
hermetically sealed
-
Features Provided
shock resistant
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference and 60.0 volts dc 3rd radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference and 60.0 volts dc 4th radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference and 60.0 volts dc 5th radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference and 60.0 volts dc 6th radio interference .
-
Body Surface Treatment
nickel or tin
-
Special Features
32 filtered functions; 18 unfiltered functions
-
Style Designator
45 filter connector
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference .
-
Load Impedance Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 3rd radio interference .
-
Load Impedance Per Function
50.0 ohms 4th radio interference .
-
Load Impedance Per Function
50.0 ohms 5th radio interference .
-
Load Impedance Per Function
50.0 ohms 6th radio interference .
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference .
-
Operating Current Rating Per Function In Amps
2.0 3rd radio interference .
-
Operating Current Rating Per Function In Amps
2.0 4th radio interference .
-
Operating Current Rating Per Function In Amps
2.0 5th radio interference .
-
Operating Current Rating Per Function In Amps
2.0 6th radio interference .
-
Mounting Facility Screw Thread Series Designator
unc
-
Mounting Facility Type And Quantity
7 threaded hole
-
Functional Terminal Type And Quantity
50 friction w/grounding strap and pin input-output
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference and 60.0 volts dc 1st radio interference .