865528-5

Circuit Breakers

CIRCUIT BREAKER

865528-5

5925-01-381-5188

5925 - Circuit Breakers

Northrop Grumman Guidance And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    corrosion resistant and hermetically sealed and shock resistant and vibration resistant and moisture resistant and fungus resistant

  • Unpackaged Unit Weight

    4.000 ounces

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct first location and 0.950 maximum at 200 pct first location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    time delay first location

  • Terminal Type And Quantity

    4 wire hook

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    0.360 inches minimum and 0.390 inches maximum

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac second location

  • Frequency In Hertz

    400.0 second location

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Trip Release Characteristic

    instantaneous second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    50.0 first location or 60.0 first location

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Features Provided

    high inrush protection

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...