A3429

Filters and Networks

FILTER,BAND PASS

A3429

5915-01-381-7769

5915 - Filters and Networks

Aiken Advanced Systems Inc

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Iii Operating Temp Range

    -55.0 to 85.0 deg celsius

  • Reference Frequency Per Function

    12.0 megahertz 2nd band pass

  • Source Impedance Rating Per Function

    50.0 ohms 3rd band pass

  • Load Impedance Per Function

    90.0 ohms 3rd band pass

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Voltage Standing Wave Ratio Per Function

    1.3 1st band pass

  • Functional Terminal Type And Quantity

    3 connector, receptacle output

  • Iii Specified Frequencies Of Discrimination Per Function

    10.00 megahertz 2nd band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    14.00 megahertz 2nd band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    16.00 megahertz 2nd band pass

  • Iii Specified Frequencies Of Discrimination Per Function

    2.00 megahertz 1st band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    20.00 megahertz 3rd band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    8.00 megahertz 1st band pass

  • Nominal Thread Size

    0.112 inches

  • Iii Body Material

    metal

  • Frequency Band Width Per Function

    10.00 megahertz 2nd band pass and

  • Frequency Band Width Per Function

    4.00 megahertz 1st band pass and

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    40.0 maximum 2nd band pass

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    40.0 maximum 3rd band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    14.0 megahertz 2nd band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    28.0 megahertz 3rd band pass

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

  • Overall Length

    3.293 inches nominal

  • Body Length

    2.293 inches nominal

  • Body Width

    2.200 inches nominal

  • Body Height

    0.750 inches nominal

  • Reference Frequency Per Function

    24.0 megahertz 3rd band pass

  • Reference Frequency Per Function

    5.0 megahertz 1st band pass

  • Source Impedance Rating Per Function

    50.0 ohms 1st band pass

  • Specification/Standard Data

    98750-8323655 manufacturers specification control

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    6.0 megahertz 1st band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    4.0 megahertz 1st band pass and

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    20.0 megahertz 3rd band pass and

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    10.0 megahertz 2nd band pass and

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    40.0 maximum 1st band pass

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 3rd band pass and

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and

  • Iii Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and

  • Frequency Band Width Per Function

    6.00 megahertz 1st band pass

  • Frequency Band Width Per Function

    28.00 megahertz 3rd band pass

  • Frequency Band Width Per Function

    20.00 megahertz 3rd band pass and

  • Frequency Band Width Per Function

    14.00 megahertz 2nd band pass

  • Iii Specified Frequencies Of Discrimination Per Function

    8.00 megahertz 2nd band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    6.00 megahertz 1st band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    4.00 megahertz 1st band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    30.00 megahertz 3rd band pass

  • Iii Specified Frequencies Of Discrimination Per Function

    28.00 megahertz 3rd band pass and

  • Iii Specified Frequencies Of Discrimination Per Function

    16.00 megahertz 3rd band pass and

  • Functional Terminal Type And Quantity

    1 connector, receptacle input

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.5 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.5 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.5 1st band pass

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Screw Thread Series Designator

    unc

  • Voltage Standing Wave Ratio Per Function

    1.3 3rd band pass

  • Voltage Standing Wave Ratio Per Function

    1.3 2nd band pass

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Load Impedance Per Function

    90.0 ohms 2nd band pass

  • Load Impedance Per Function

    90.0 ohms 1st band pass

  • Source Impedance Rating Per Function

    50.0 ohms 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...