6011920-022
Circuit Breakers
CIRCUIT BREAKER
6011920-022
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct first location and 60.000 maximum at 200 pct first location
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
1.026 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Internal Trip Release Configuration
series trip all locations
-
Frequency In Hertz
47.0 second location or 440.0 second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches nominal
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 all locations
-
Mounting Slot Width
0.164 inches nominal
-
Manual Actuator Type And Quantity
3 toggle
-
Unpackaged Unit Weight
2.000 pounds
-
Mounting Facility Type And Quantity
3 slot and 6 threaded hole
-
Frequency In Hertz
47.0 first location or 440.0 first location
-
Case Material
plastic
-
Trip Release Characteristic
instantaneous third location
-
Terminal Type And Quantity
6 threaded stud
-
Body Style
multipole-multiple actuator type
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
-
Trip Release Characteristic
time delay first location
-
Body Width
2.072 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct second location and 60.000 maximum at 200 pct second location
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc third location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay second location
-
Center To Center Distance Between Terminals Parallel To Length
3.547 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
125.0 amperes ac first location
-
Body Height
2.609 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Body Length
5.800 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
125.0 amperes ac second location
-
Boss Height
0.219 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location