ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole two
-
Center To Center Distance Between Terminals Parallel To Length
1.160 inches minimum and 1.220 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.720 inches minimum and 0.780 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Body Height
2.350 inches minimum and 2.400 inches maximum
-
Body Length
2.200 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Bushing Length
0.235 inches minimum and 0.250 inches maximum
-
Body Width
2.270 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations
-
Terminal Type And Quantity
6 tab w/screw
-
Case Material
plastic
-
Unpackaged Unit Weight
0.650 pounds
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Inclosure Protection Type For Which Designed
shock resistant and sand resistant and dusttight and humidity resistant and corrosion resistant and explosion proof
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.470 inches minimum and 1.530 inches maximum
-
Fragility Factor
moderately rugged