SM600BA75N12
Circuit Breakers
CIRCUIT BREAKER
SM600BA75N12
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Overall Length
3.250 inches nominal
-
Reset Method
automatic
-
Mounting Surface To Terminal End Distance
4.030 inches nominal
-
Unthreaded Mounting Hole Diameter
0.172 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac single location and 3600.0 dc single location
-
Frequency In Hertz
400.0 single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Trip Release Characteristic
time delay single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.940 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Internal Trip Release Configuration
series trip single location
-
Case Material
metal
-
Pole Quantity
1
-
Trip Release Method
thermal single location
-
Circuit Protection Type
overcurrent single location
-
Body Width
1.200 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
75.0 amperes ac single location and 75.0 amperes dc single location