Technical Characteristics
-
~1
data on certain environmental and performance r
-
Test Data Document
12464-b86k0210 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Winding Power Rating
160.0 volts-amperes single component single primary
-
Mounting Hole Diameter
0.170 inches minimum single group and 0.230 inches maximum single group
-
Overall Diameter
2.000 inches maximum
-
Mounting Facility Quantity
1 single group
-
Maximum Operating Temp
130.0 deg celsius
-
Input-Output Phase Relationship
single phase to single phase single component
-
Reliability Indicator
not established
-
Mounting Method
unthreaded hole single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inclosure Type
fully inclosed
-
Frequency Rating
40.0 kilohertz nominal single component
-
Terminal Type And Quantity
5 turret
-
Body Length
1.250 inches maximum
-
Winding Operating Voltage
140.00 ac volts nominal single component single primary
-
Winding Operating Current
2.2 amperes ac nominal single component single secondary