AM4-A3A3A3A6-A-80/80/80/2-120A/P
Circuit Breakers
CIRCUIT BREAKER
AM4-A3A3A3A6-A-80/80/80/2-120A/P
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
relay trip fourth location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.700 minimum at 200 pct second location and 10.100 maximum at 200 pct second location
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.500 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.015 maximum at 200 pct fourth location
-
Body Width
3.040 inches nominal
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Internal Trip Release Configuration
series trip first location
-
Boss Height
0.138 inches nominal
-
Internal Trip Release Configuration
series trip second location
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.700 minimum at 200 pct third location and 10.100 maximum at 200 pct third location
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac first location
-
Internal Trip Release Configuration
series trip third location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac second location
-
Center To Center Distance Between Terminals Parallel To Length
1.655 inches minimum and 1.695 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac fourth location
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.700 minimum at 200 pct first location and 10.100 maximum at 200 pct first location
-
Manual Actuator Type And Quantity
4 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Mounting Surface To Terminal End Distance
2.625 inches nominal
-
Case Material
plastic
-
Pole Quantity
4