0122274-1
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
0122274-1
Navy United States Department Of The
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Temp Rise
25.0 deg celsius
-
Overall Height
4.880 inches nominal
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Overall Length
12.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Unthreaded Mounting Hole Diameter
0.246 inches minimum and 0.260 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
11.000 inches nominal
-
Features Provided
shock resistant
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.000 inches nominal
-
Maximum Voltage Drop Per Function
0.5 volts ac 1st radio interference
-
Special Test Features
ahcg afga cqrg
-
Operating Temp Range
-20.0/+60.0 deg celsius
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 1st radio interference 1st function
-
Body Width
0.4000 inches nominal
-
Maximum Voltage Drop Per Function
0.5 volts ac 2nd radio interference
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Body Height
4.000 inches nominal
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Operating Voltage Rating And Type Per Function
50.0 volts ac 4th radio interference 4th function
-
Operating Current Rating Per Function In Amps
15.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Current Rating Per Function In Amps
15.0 2nd radio interference
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps
15.0 3rd radio interference
-
Maximum Voltage Drop Per Function
0.5 volts ac 3rd radio interference
-
Body Length
11.000 inches nominal
-
Operating Current Rating Per Function In Amps
15.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 4th radio interference
-
Functional Terminal Type And Quantity
2 threaded stud input 1st function
-
Maximum Voltage Drop Per Function
0.5 volts ac 4th radio interference
-
Functional Terminal Type And Quantity
4 threaded stud output 2nd function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference