Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    460.0 ac all locations

  • Body Length

    5.800 inches nominal

  • Body Width

    6.276 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Boss Height

    0.219 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    6 toggle

  • Mounting Facility Type And Quantity

    12 threaded hole

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Terminal Type And Quantity

    12 compression

  • Center To Center Distance Between Terminals Parallel To Length

    4.750 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Pole Quantity

    6

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    50.000 minimum at 200 pct all locations and 105.000 maximum at 200 pct all locations

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one, two, three, four, five, and six linked

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...