H505A001-102

Circuit Breakers

CIRCUIT BREAKER

H505A001-102

5925-01-407-2542

5925 - Circuit Breakers

Bae Systems Information And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc first location

  • Boss Height

    0.150 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    3.015 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac third location

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Body Length

    2.530 inches maximum

  • Mounting Surface To Terminal End Distance

    2.645 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    8 compression

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Frequency In Hertz

    60.0 first location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Frequency In Hertz

    60.0 second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Nominal Thread Size

    0.138 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Frequency In Hertz

    60.0 third location

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac second location

  • Manual Actuator Type And Quantity

    4 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...