Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    3.015 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac third location

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Body Length

    2.530 inches maximum

  • Mounting Surface To Terminal End Distance

    2.645 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Pole Quantity

    4

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac second location

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    5.0 dc fourth location

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Frequency In Hertz

    60.0 third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Nominal Thread Size

    0.138 inches

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Frequency In Hertz

    60.0 second location

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Frequency In Hertz

    60.0 first location

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Terminal Type And Quantity

    8 compression

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...