6510-002-5

Circuit Breakers

CIRCUIT BREAKER

6510-002-5

5925-01-424-2425

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    3.250 inches maximum

  • Mounting Surface To Terminal End Distance

    4.260 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Specification/Standard Data

    81349-mil-c-83383 government specification and 81349--83383/02 government specification

  • Internal Trip Release Configuration

    series trip single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.940 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3600.0 ac single location

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Style

    single pole type

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Reset Method

    automatic

  • Body Width

    1.200 inches maximum

  • Terminal Type And Quantity

    2 threaded stud

  • ~1

    single location

  • ~1

    data on certain environmental and performanc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location and 115.0 ac single location

  • Trip Release Ambient Temp Rating

    -54.0 deg celsius minimum single location and 71.0 deg celsius maximum single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 200 pct single location and 0.300 minimum at 1000 pct single location and 1.200 minimum at 400 pct single location and 40.000 maximum at 200 pct single location and 6.400 maximum at 400 pct single location and 1.200 maximum at 1000 pct

  • Test Data Document

    81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...