JA2S-C3C15-EB-01-D-NU
Circuit Breakers
CIRCUIT BREAKER
JA2S-C3C15-EB-01-D-NU
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac second location and 10.0 amperes dc second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac second location and 1000.0 dc second location
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 first location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Trip Release Characteristic
time delay second location
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Frequency In Hertz
60.0 second location or 50.0 second location or 400.0 second location
-
Mounting Facility Type And Quantity
4 clip
-
Trip Release Characteristic
time delay first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac first location and 1000.0 dc first location
-
Frequency In Hertz
60.0 first location or 50.0 first location or 400.0 first location
-
Internal Trip Release Configuration
series trip first location
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal second location
-
Body Style
multipole-multiple actuator type
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac second location
-
Circuit Protection Type
overcurrent second location
-
Body Length
2.000 inches nominal
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 150 pct second location and 6.000 maximum at 150 pct second location
-
Circuit Protection Type
overcurrent first location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac first location and 10.0 amperes dc first location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Pole Quantity
2
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip w/remote trip feature second location
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 second location
-
Terminal Type And Quantity
5 knife blade
-
Manual Actuator Type And Quantity
2 toggle
-
Trip Release Method
magnetic first location
-
Trip Release Duty Cycle
continuous second location
-
Body Width
1.500 inches nominal
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 150 pct first location and 70.000 maximum at 150 pct first location
-
Trip Release Method
magnetic second location
-
Case Material
plastic
-
Boss Height
0.130 inches nominal