MIL-C-13516/4

Circuit Breakers

CIRCUIT BREAKER

MIL-C-13516/4

5925-01-430-0026

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Overall Length

    3.160 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.870 inches nominal

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.060 inches nominal

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and vibration resistant and fungus resistant

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes dc single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Thread Series Designator

    unf

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.