PP16-1-4.00A-XX-S

Circuit Breakers

CIRCUIT BREAKER

PP16-1-4.00A-XX-S

5925-01-446-4790

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Bushing Length

    0.400 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac single location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • End Item Identification

    f-15i lantirn

  • Ultimate Trip Time Per Pole In Seconds

    7.000 nominal single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    36.0 ac single location

  • Body Length

    1.375 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Current Rating And Type In Amps

    0.1 ac

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 135 pct single location and 7.000 maximum at 135 pct single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Mounting Surface To Terminal End Distance

    1.960 inches nominal

  • Pole Quantity

    1

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    unef

  • Switch Terminal Type

    knife blade

  • Switch Voltage Rating And Type In Volts

    32.0 ac and 32.0 dc

  • Body Style

    single pole type

  • Body Width

    0.680 inches nominal

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Mounting Facility Type And Quantity

    threaded bushing

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Switch Location And Position Designation

    external at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.125 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...