UPG-66-1REG4-51-302-01

Circuit Breakers

CIRCUIT BREAKER

UPG-66-1REG4-51-302-01

5925-01-460-2577

5925 - Circuit Breakers

Philips Technologies

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.130 inches nominal

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • End Item Identification

    f-15i

  • Body Length

    2.032 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Width

    1.515 inches maximum

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    65.0 dc maximum all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Nominal Thread Size

    0.138 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    65.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 100 pct all locations and 10.000 maximum at 125 pct all locations

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Terminal Type And Quantity

    4 tab w/screw

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...