Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac resistive load and 15.0 amperes dc resistive load
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Precious Material And Location
terminals gold
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Overall Height
1.310 inches nominal
-
Features Provided
polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Overall Width
0.525 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes ac motor load and 4.0 amperes dc motor load
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Special Features
temp range minus 70.0 deg to plus 125.0 deg c; pickup voltage 18.0 vdc max; hold voltage 7.0 vdc; drop-out voltage 1.5 vdc min; coil current 0.11 amp max; terminal strength 5.0 lbs nominal; pins are underplated (except polarizing pin is tinned) prior to
-
~1
gold plating (per mil-g-45204, type ii, class