CD3-A2A3A3-AE-50-1

Circuit Breakers

CIRCUIT BREAKER

CD3-A2A3A3-AE-50-1

5925-01-465-2670

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 slot and 6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 30.0 dc

  • Body Style

    8c multipole-multiple actuator type

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.844 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    4.781 inches nominal

  • Body Width

    3.118 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 105.000 maximum at 200 pct all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...