MIL-PRF-23648/20
Resistors
RESISTOR,THERMAL
MIL-PRF-23648/20
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-prf-23648 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
Resistance Tolerance At A Specified Temp In Percent
-7.0/+7.0 5th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 3rd resistance-temperature point
-
Body Outside Diameter
0.070 inches minimum and 0.130 inches maximum
-
Maximum Operating Temp
125.0 deg celsius
-
Terminal Length
1.500 inches minimum
-
Resistance Tolerance At A Specified Temp In Percent
-15.0/+15.0 1st resistance-temperature point
-
Zero Power Resistance
2.000 kilohms
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Style Designator
sealed or coated bead
-
Zero Power Resistance At Specified Temp
2.0 kilohms 4th resistance-temperature point
-
Inclosure Type
encapsulated
-
Zero Power Resistance At Specified Temp
368.0 ohms 6th resistance-temperature point
-
Ambient Temp At Full Rated Power
125.0 deg celsius
-
Resistance Tolerance At A Specified Temp In Percent
-15.0/+15.0 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
100.6 ohms 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
109.8 kilohms 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
25.0 deg celsius 4th resistance-temperature point
-
Body Length
0.250 inches maximum
-
Specification/Standard Data
81349-mil-prf-23648/20 government specification
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point
-
~1
type data on certain environmental and performa
-
Resistance Tolerance At A Specified Temp In Percent
-5.0/+5.0 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
115.4 kilohms 2nd resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
2.0
-
Resistance Tolerance At A Specified Temp In Percent
-7.0/+7.0 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-9.0/+9.0 6th resistance-temperature point
-
Thermal Time Constant In Seconds
25.0
-
Zero Power Resistance At Specified Temp
810.0 ohms 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
184.6 ohms 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-9.0/+9.0 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 5th resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-5.0/+5.0
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 8th resistance-temperature point
-
Terminal Diameter
0.125 inches minimum and 0.127 inches maximum
-
Zero Power Resistance At Specified Temp
5.7 kilohms 3rd resistance-temperature point
-
Maximum Power Dissipation Rating
200.00 milliwatts
-
Temp Points For Resistance Readings At Zero Power
-15.0 deg celsius 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 7th resistance-temperature point