AP-117-1-61-103

Circuit Breakers

CIRCUIT BREAKER

AP-117-1-61-103

5925-01-479-7742

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal and 2 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • End Item Identification

    5820-01-454-0338

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Bushing Length

    0.380 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 wire hook

  • Body Width

    1.875 inches maximum

  • Nominal Thread Size

    0.375 inches and 0.138 inches

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Thread Quantity Per Inch

    32 and 32

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Thread Series Designator

    unef and unc

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...