Circuit Breakers
CIRCUIT BREAKER
7068566
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39019 specification specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications,
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.950 maximum at 200 pct all locations and 0.240 maximum at 400 pct all locations and 0.055 minimum at 200 pct all locations and 0.060 maximum at 800 pct all locations
-
Pole Quantity
2
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
End Item Identification
weapon launch consol assembly for los angeles class submarine 688
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
0.625 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Terminal Type And Quantity
4 screw
-
Trip Release Ambient Temp Rating
23.0 deg celsius minimum all locations and 27.0 deg celsius maximum all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Inclosure Protection Type For Which Designed
corrosion resistant and fungus resistant and hermetically sealed
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Width
0.906 inches maximum
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
60.0 all locations or 400.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.720 inches minimum and 0.780 inches maximum
-
Body Length
1.562 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
800.0 all locations
-
Thread Series Designator
unef
-
Auxiliary Switch Function And Quantity
1 alarm
-
Specification/Standard Data
81349-mil-c-39019/4 government specification
-
Switch Contact Arrangement
double pole, single throw, normally closed
-
Body Width
1.281 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
~1