462-7068566-95
Circuit Breakers
CIRCUIT BREAKER
462-7068566-95
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
reflecting general type data on certain environmental
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
800.0 single location
-
Mounting Surface To Terminal End Distance
1.810 inches maximum
-
Thread Series Designator
unef
-
Frequency In Hertz
60.0 single location or 400.0 single location
-
Trip Release Method
magnetic single location
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Actuator Position Designation
at each pole
-
End Item Identification
weapon launch consol assembly for los angeles class submarine 688
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Case Material
metal
-
Trip Release Ambient Temp Rating
23.0 deg celsius minimum single location and 27.0 deg celsius maximum single location
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac single location
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Specification/Standard Data
81349-mil-c-39019/2 government specification
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Contact Arrangement
single pole, single throw, normally closed
-
Body Length
1.562 inches maximum
-
Test Data Document
81349-mil-c-39019 specification specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications,
-
Inclosure Protection Type For Which Designed
fungus resistant and corrosion resistant and hermetically sealed
-
Auxiliary Switch Function And Quantity
1 alarm
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.240 maximum at 400 pct single location and 0.055 minimum at 200 pct single location and 0.950 maximum at 200 pct single location and 0.060 maximum at 800 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location
-
Switch Location And Position Designation
internal at pole one