462-7068566-97

Circuit Breakers

CIRCUIT BREAKER

462-7068566-97

5925-01-497-1180

5925 - Circuit Breakers

Naval Sea Systems Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • End Item Identification

    weapon launch consol assembly for los angeles class submarine 688

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Switch Location And Position Designation

    internal at pole three

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Trip Release Ambient Temp Rating

    23.0 deg celsius minimum all locations and 27.0 deg celsius maximum all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant and hermetically sealed

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.344 inches minimum and 1.404 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Actuator Position Designation

    at pole two

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Body Length

    1.562 inches maximum

  • Terminal Type And Quantity

    6 screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 all locations

  • Body Width

    1.937 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.240 maximum at 400 pct all locations and 0.950 maximum at 200 pct all locations and 0.060 maximum at 800 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Special Features

    circuit breaker has three pole, single throw, normally closed switch contact arrangement

  • Specification/Standard Data

    81349-mil-c-39019/6 government specification

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Test Data Document

    81349-mil-c-39019 specification specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications,

  • ~1

    reflecting general type data on certain environmental

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.