MIL-PRF-39019/4

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-39019/4

5925-01-498-4755

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.950 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Part Name Assigned By Controlling Agency

    circuit breaker

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and salt water resistant

  • Thread Quantity Per Inch

    10

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • End Item Identification

    los angeles class ssn (688), ship control station, enclosure assembly mini station, mode select console

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Location And Position Designation

    external between pole one and two

  • Body Length

    1.562 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 all locations

  • Switch Voltage Rating And Type In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 ac all locations

  • Switch Contact Arrangement

    double pole, single throw, normally closed

  • Body Width

    1.281 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Frequency In Hertz

    400.00 all locations

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations and 5.0 amperes dc all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...