Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    63.000 nominal at 125 pct first location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    63.000 nominal at 125 pct second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.000 nominal at 125 pct fourth location

  • Boss Height

    1.042 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    63.000 nominal at 125 pct third location

  • Special Features

    1st pole has single pole double throw auxiliary switch

  • Body Length

    3.015 inches nominal

  • Case Material

    metal

  • End Item Identification

    5895-01-467-7213

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Width

    2.490 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    120.0 milliamperes dc fourth location

  • Mounting Surface To Terminal End Distance

    2.529 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc fourth location

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    70.0 deg celsius nominal all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac second location

  • Pole Quantity

    4

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...