99002A8046-24
Circuit Breakers
CIRCUIT BREAKER
99002A8046-24
Marine Corps Logistics Command
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
63.000 nominal at 125 pct all locations
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Bushing Length
0.140 inches nominal
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Mounting Surface To Terminal End Distance
2.404 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Boss Height
1.042 inches nominal
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
thermal-magnetic all locations
-
Special Features
first pole only has single handle - controls both poles;second pole does not protrude through panel - except mounting screws
-
Body Length
3.015 inches nominal
-
Case Material
metal
-
End Item Identification
5895-01-467-7213
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Body Width
2.490 inches nominal
-
Trip Release Ambient Temp Rating
70.0 deg celsius nominal all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Mounting Facility Type And Quantity
4 threaded stud
-
Terminal Type And Quantity
4 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal