SC5925-0013-3

Circuit Breakers

CIRCUIT BREAKER

SC5925-0013-3

5925-01-502-2470

5925 - Circuit Breakers

Drs Icas Llc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Nonturn Device Diameter

    0.140 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.875 inches nominal

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Terminal Type And Quantity

    4 wire hook

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Nonturn Device Radius

    0.625 inches nominal

  • Case Material

    metal

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    1.500 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 125 pct all locations and 40.000 maximum at 125 pct all locations

  • Thread Series Designator

    unef

  • Frequency In Hertz

    50.0 all locations or 90.0 all locations

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Length

    0.130 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    0.625 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    1.875 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...