UND/122A10 00M
Circuit Breakers
CIRCUIT BREAKER
UND/122A10 00M
Daimler Trucks North America Llc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
End Item Identification
nsn2320-01-432-4847; weapon system - truck, m-915 series, m-916a1(let)
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.500 nominal at 400 pct single location
-
Special Features
terminals - two 10-32 studs; no bracket; length 1.240 inches, width 0.790 inches, height 0.640 inches; operating temperature - minus 10 degrees f to 150 degrees f
-
Terminal Type And Quantity
2 threaded stud
-
Mounting Facility Type And Quantity
2 terminal
-
Operating Voltage Type And Rating Per Pole In Volts
12.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
400.0 single location
-
Case Material
metal
-
Ultimate Trip Time Per Pole In Seconds
3.500 nominal single location
-
Pole Quantity
1
-
Trip Release Method
thermal single location
-
Circuit Protection Type
overcurrent single location