111987-001
Coils and Transformers
TRANSFORMER,POWER
111987-001
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
20.0 amperes nominal b single component single primary
-
Body Height
0.550 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Reliability Indicator
not established
-
Terminal Type And Quantity
6 wire lead
-
Inclosure Type
fully inclosed
-
Winding Operating Current
70.0 amperes nominal b single component single secondary
-
Body Outside Diameter
1.210 inches maximum
-
Special Features
windings: 1-2a, 2b-3, 6 turns, awg wire (strands) no. 38 (25); 4-5, 300 turns, awg no. 40; operating power output: 40 wtyp; dc resistance: winding 1-2 & 2-3, 56.5 mohms, winding 4-5, 25 ohms
-
End Item Identification
recorder-monitor
-
Frequency Rating
50.0 hertz nominal single component or 60.0 hertz nominal single component