09-00962-002
Coils and Transformers
REACTOR
09-00962-002
REACTOR
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Width
0.935 inches minimum and 0.940 inches maximum
-
Turn Quantity
4 single component single winding
-
Rating Method
winding turns single component single winding
-
Winding Operating Current
7.0 amperes maximum of standard range b and better single component single winding and 20.0 amperes maximum of standard range b and better drop siding single component single winding
-
End Item Identification
61-41852-001 used on sshpa
-
Special Features
requested name reactor,power toroidal
-
Frequency Rating
200.0 kilohertz nominal all components
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Conductor Size
0.03196 inches american wire gage all components single winding
-
Inclosure Type
fully inclosed
-
Winding Quantity
4 single component
-
Mounting Facility Quantity
1 all groupings
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Overall Height
0.540 inches minimum and 0.550 inches maximum