M39019/03-333S
Circuit Breakers
CIRCUIT BREAKER
M39019/03-333S
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
~1
type data on certain environmental and performa
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
End Item Identification
aft steering unit
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Nonturn Device Location
at 12 oclock
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
-
Terminal Type And Quantity
4 tab w/screw
-
Nominal Thread Size
0.375 inches
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations and 240.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
60.0 all locations or 400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations and 10.0 amperes dc all locations
-
Specification/Standard Data
81349-mil-prf-39019/3 government specification
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Thread Series Designator
unef
-
Special Features
2 mounting screws to enhance vibration resistance; circuit breaker furnished with nonturn devise
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations
-
Body Width
1.281 inches maximum
-
Ultimate Trip Time Per Pole In Seconds
3.000 minimum all locations and 60.000 maximum all locations
-
Features Provided
high inrush protection
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Nonturn Device Radius
0.325 inches nominal