APL-1111-1REC4-62-303-M
Circuit Breakers
CIRCUIT BREAKER
APL-1111-1REC4-62-303-M
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Width
3.015 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Body Length
2.530 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Boss Height
0.135 inches minimum and 0.165 inches maximum
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Mounting Surface To Terminal End Distance
2.495 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
End Item Identification
an/sqq-89(v) 15 unit 735 & 762, pwr dist, receiver i/o & pwr dist, data prcsr
-
Terminal Type And Quantity
8 threaded stud
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Switch Location And Position Designation
internal at pole four
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 65.0 dc all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Terminal Type
quick disconnect, male
-
Manual Actuator Type And Quantity
4 toggle
-
Unpackaged Unit Weight
14.800 ounces
-
Case Material
plastic
-
Pole Quantity
4